Erori – coduri service masini de spalat Whirlpool

lavaroupa21

F01

Probleme alimentare cu apa sau presostat blocat.
Verificati functionalitatea electrovalvelor (curatati filtrele, alimentarea cu apa si current).
Verificati functionalitatea presostatului (furtune sparte sau infundate).
Verificati conexiunile electrovalvelor, presostatului si modulului.
Verificati modulul.

==============================

F02 / FA / F09

Eroare Aquastop.
Daca este apa in tava de jos:
Verificati daca sunt scurgeri (furtune sparte, desprinse).
Verificati spumare excesiva.
Daca nu este apa in tava de jos:
Verificati aquastop-ul.
Verificati modulul.

==============================

F03

Evacuare prelungita.
Verificati racodurile de evacuare sa nu fie obturate sau gatuite.
Verificati filtrul pompei.
Verificati conexiunile pompei.
Verificati pompa.

==============================

F04

Incalizire prelungita.
Verificati rezistenta de incalzire.
Verificati NTC.
Verificati conexiunile rezistentei, NTC-ului si a modulului.

==============================

F05

Eroare NTC.
Verificati rezistenta NTC.
Verificati conexiunile intre NTC si modulul electronic.

==============================

F06

Eroare tahometru motor.
Verificati rezistenta tahometrului.
Verificati motorul.
Verificati conexiunile intre motor si modul.
Verificati CUREA rupta/cazuta.

==============================

F07

Eroare triac motor.
Verificati modulul electronic.

==============================

F08 / F12

Eroare rezistenta.
Verificati valoarea rezistentei.
Verificati conexiunile.
Verificati modulul.

==============================

F13

Ledul de la usa clipeste dupa inceperea programului.
Verificati mecanismul incuietorii.
Verificati daca usa se inchide (ciocul manerului blocheaza).

==============================

F14

Eroare eeprom/memorie.
Variatiile de tensiune pot fi cauza pentru care memoria modului se sterge.
Verificati modulul.

==============================

F15

Eroare blocator tambur (numai pentru masinile cu incarcare pe verticala).
Eroarea este afisata numai in timpul programului test.
Verificati daca electromagnetul este pe pozitie.
Verificati pozitia senzorului (cititorului) blocatorului.
Verificati valoarea rezistentei senzorului.
Verificati conexiunile.

==============================

F21

Eroare de comunicare intre modul si panoul frontal (display).
Verificati conexiunile intre module.
Verificati modulul electronic.

==============================

F23

Eroare presostat.
Verificati contactele presostatului.
Verificati conexiunile dintre presostat si modulul electronic.
Verificati panoul frontal.

==============================

F24

Eroare preaplin (pompa / pesostat).
Verificati racordul de evacuare.
Verificati pompa de evacuare si filtrul.
Verificati presostatul.
Verificati conexiunile.

==============================

F26

Eroare pompa.
Verificati presostatul.
Verificati conexiunile.
Verificati pompa.
Verificati modulul.

==============================

F27

Eroare releu motor.
Verificati conexiunile motorului.
Verificati modulul.

==============================

F28

Eroare motor.
Verificati conexiunile.
Verificati motorul.
Verificati modulul.

==============================

F18/Fod

Exces de spuma.
Verificati presostatul (conexiuni) sa nu fie afectat de spuma.
Verificati pompa (contacte).
Verificati racordurile si furtunele de la presostat.
Verificati instalatia sanitara la evacuare (sa nu fie infundata).

Coduri si erori Indesit-Moon

COD-EROARE-INDESIT-MOON-ROM

 

f01 light 4, motor triac
f02 light 3 motor, jammed/ tacho
f03 lights 3&4 Ntc fault
f04 light 2. pressure sw stuck on empty
f05 lights 2&4, pressure sw stuck on full
f06 lights 2&3, N/A?
f07 lights 2&3&4 heater relay
f08 light 1. heater relay
f09 lights 1&4 eprom/setup error
f10 lights 1&3, pressure switch not sensing
f11 lights 1&3&4, pump/draining error
f12 lights 1&2, communication error
f13 lights 1&2&4, dryer ntc/ fan motor
f14 lights 1&2&3, dryer heater
f15 lights 1&2&3&4, dryer heater relay
f16 N/A
f17 light 4, door lock
f18 light 3 comms error (3 phase motor) power board

 

Detalii:  F01,  f02,  f03, ……., f18.

List of faults, malfunctions and Warnings:

F01: Triac Motor short circuit
– Check for water leaks that may affect connector J9 causing the relevant contacts to short
– Check the motor terminal block (possible problems due to chemical effects of work residuals on the contacts which may cause short-circuiting)
– Replace Card

F02: Motor blocked, Tachometrics in Short Circuit/Open
– Check motor if blocked
– Check efficiency of J9 connector on card
– Check the tachometric winding verifying an ohmic resistance reading of 115 – 170 ohm between pins
1 and 2 on wiring connector J9. In case of short circuit/open circuit check the wiring between pins 1 and 2 of J9 relevant to the tachometrics. With three-phase motor, make sure there is ohmic continuity between J9 pins 6 and 7.
– Replace motor
– Replace card

F03: NTC Open or in Short Circuit or washing heater relay stuck (signalled in presence of full load)
– Check efficiency of J8 connector contacts on card
– Check NTC verifying that the ohmic resistance value at room temperature 20°C is approx. 20Kohm on J8 wiring connector pin 11 and 12.
– If the measurement is incorrect check J8/NTC wiring continuity
Check the same parameter directly on NTC
– Replace NTC
– Replace Card

F04: Simultaneous empty and overflow (pressure switch stuck on empty).
If the pressure switch contact is stuck on empty the washing-machine loads water until reaching the overflow. The drain pump is automatically started by the contact on the overflow pressure switch.
– Check efficiency of J3 connector contacts on card
– Check pressure switch status by checking ohmic continuity on wiring connector J3 pins 2 and 4 (it must only be present with tub empty), pins 2 and 3 (it must only be present with water in the drum) and pins 2 and 1 (it must only be present with water in the tub above normal level, more than halfway up door glass).
– Check wiring of connector J3/pressure switch
– Replace pressure switch
– Replace card.

F05: Pump Blocked or pressure switch empty not reached
– Check efficiency of J9 connector on card, verifying a voltage of 220V between pins 8 and 9
– Check that pump if being fed
– Check Pump Filter + wall drain
– Change Pump
– Replace Card

F06: No on AVD and AVL

F07: No Wash Heating Element Absorption (the fault is only signalled with the pressure switch on empty)
– Check efficiency of J3 connector contacts on card
– Check continuity of the wash heating element on J3 connector pins 5 and 6. The 1800W 230V heating element has a resistance of 25 ohm.
– Check connection of pressure switch J3 connector pins 2 and 3: there must not be ohmic continuity (shared with full load).
Check connection of pressure switch J3 connector pins 2 and 4: there must be ohmic continuity
– Replace Heating Element
– Replace Pressure Switch
– Replace Card

F08: Wash Heater Relay Stuck (signalled in presence of empty) or pressure switch stuck on Full (simultaneously empty and full)
– Check efficiency of J3 connector contacts on card
– Check pressure switch status by checking ohmic continuity on wiring connector J3 pins 2 and 4 (it must only be present with tub empty), pins 2 and 3 (it must only be present with water in the drum) and
pins 2 and 1 (it must only be present with water in the tub above normal level, more than halfway up door glass).
– Check wiring J3/pressure switch
– Check connection of heating element J3 connector pins 5 and 6.
– Replace pressure switch
– Replace Card

F09: Machine Setup Error (Eeprom error)
– In case of production card with Eeprom soldered: replace the card and Eeprom
– In case of replacement of Eeprom and card, check correct housing of Eeprom on card socket

F10: No full and empty signal
– Check efficiency of J3 connector contacts on card
– Check pressure switch status by checking ohmic continuity on wiring connector J3 pins 2 and 4 (it must only be present with tub empty), pins 2 and 3 (it must only be present with water in the drum) and
pins 2 and 1 (it must only be present with water in the tub above normal level, more than halfway up door glass).
– Check wiring of connector J3/Pressure switch
– Replace Pressure Switch
– Replace Card

F11: No Pump Feedback (Drain pump disconnected or winding broken)
– Check efficiency of J9 connector on card
– Check continuity of the Pump on J15 connector pins 1 and 2 (in case of washing-machine with Easy Door door lock) or on J9 connector pins 8 and 9 (in case of conventional door lock), checking a resistive value equal to 170 ohm.
– Check wiring of connector J15 (or J9)/Pump
– Replace Pump
– Replace Card

F12: No Communication Display/LED Card-Main Board
– Check efficiency of contacts on card of J11 connector
– Check the continuity of J11 connector-display card 5-pin connector
– Replace Main Board
– Replace Display Card/LED

F13: Drying NTC sensor open / Drying system NTC wiring disconnected
Check efficiency of J10 connector on card
Check NTC on J10 connector pins 7 and 8 verifying that the ohmic value of the sensor at room temperature 20°C is approx. 20Kohm
Check continuity of NTC/J10 connectors wiring
Replace NTC
Replace card

F14: Drying heater open or not connected
Check efficiency of J2 connector contacts on card
Check continuity of drying heater on J2 wiring connector pins 1 and 2, verifying that the ohmic value of the 1300W 230V heating element is approx. 40Kohm
Check wiring of connector J10/drying heater
Replace heating element
Replace card

F15: Drying heater always on (drying relay contact stuck or drying Triac short circuit)
Check efficiency of J2 connector contacts on card of
Check wiring of connector J2/drying heater
Check wiring of connector J3/pressure switch
Replace card

F16: Drum locking (top-loading only)

F17: Door lock unfed/open (with Easy Door)
– Check presence of 230V mains power on J4 wiring connector inserted on card between pins 3 and 4,
(not present with machine on standby) and presence of power from 230V door lock between pins 3 and 5
– Check ohmic continuity of the door microswitch on J4 connector inserted on card between pins 1 and 2 (with door closed/on open/off)
– Check continuity of J4/door lock wiring
– Check door hooking
– Replace door lock
– Replace card

F17: Door lock unfed/open (conventional door lock, not Easy Door)
– Check presence of 230V mains power on J4 wiring connector inserted on card between pins 2 and 3,
(not present with machine on standby) and presence of power from 230V door lock between pins 3 and 1
– Check door hooking
– Replace door lock
– Replace card

F18 –> Communication error microprocessor / DSP (Digital Signal Processor)

Dan
%d blogeri au apreciat: